{"product_id":"eaton-dry-type-transformer-3phase-45kva-480v-208y-120v","title":"Eaton 45 kVA Ventilated Dry-Type Transformer 480V Delta to 208Y\/120V Aluminum Windings NEMA 2 (V48M28T4516)","description":"\u003cp data-start=\"134\" data-end=\"474\"\u003eThe Eaton V48M28T4516 general purpose ventilated transformer delivers reliable and energy-efficient power distribution for commercial and industrial applications. Designed to meet DOE 2016 efficiency standards, this 45 kVA dry-type transformer ensures optimized performance while reducing operational energy costs.\u003c\/p\u003e\n\u003cp data-start=\"476\" data-end=\"802\"\u003eEngineered with aluminum windings and a 220°C insulation system, this unit provides excellent thermal durability and long-term reliability under demanding load conditions. Its NEMA 2 enclosure offers protection for indoor environments, while the fungus-proof construction enhances performance in humid or challenging settings.\u003c\/p\u003e\n\u003cp data-start=\"804\" data-end=\"1157\"\u003eWith flexible installation options, including upright floor or wall mounting, and multiple tap configurations for voltage adjustment, this transformer supports diverse electrical infrastructure requirements. Built to meet UL and NEMA standards, it is an ideal solution for facilities requiring dependable voltage conversion from 480V delta to 208Y\/120V.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEnergy-efficient ventilated dry-type transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekVA Rating\u003c\/td\u003e\n\u003ctd\u003e45 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e480V Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e208Y\/120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480 Vac to 208Y\/120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Material\u003c\/td\u003e\n\u003ctd\u003eAluminum windings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Class\u003c\/td\u003e\n\u003ctd\u003e220°C insulation system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rise\u003c\/td\u003e\n\u003ctd\u003e150°C rise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eNEMA 2 indoor enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eFR940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eFloor-mounted or wall-mounted (upright only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTap Configuration\u003c\/td\u003e\n\u003ctd\u003e2 taps at +2.5%, 4 taps at -2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency Standard\u003c\/td\u003e\n\u003ctd\u003eDOE 2016 compliant (10 CFR Part 431)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound Level\u003c\/td\u003e\n\u003ctd\u003eComplies with NEMA ST-20 standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeathershield\u003c\/td\u003e\n\u003ctd\u003eWS58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Connection\u003c\/td\u003e\n\u003ctd\u003e280B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eFungus-proof design for enhanced durability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e36.88 in x 24.88 in x 21.13 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e436 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year from installation or 18 months from shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50612725121257,"sku":"V48M28T4516","price":4412.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1706\/8839\/files\/VENTILATED-GEN-PURP-XFMR_FM_169a6638-6964-4f90-b91c-02330f43e69e.jpg?v=1774422805","url":"https:\/\/www.avendor.com\/products\/eaton-dry-type-transformer-3phase-45kva-480v-208y-120v","provider":"Avendor","version":"1.0","type":"link"}