APC Symmetra LX 4kVA Scalable to 8kVA N+1 Tower UPS, 220–240V / 380–415V

Save $5,287.01
APCSKU: SYA4K8I
QUANTUM Authorized
Google Top Quality Store

Price:
Sale price$11,827.99 Regular price$17,115.00
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The APC Symmetra LX SYA4K8I delivers scalable, high-performance power protection with true N+1 redundancy in a compact tower design. Designed for small to medium server rooms, networking applications, and edge environments, it offers seamless scalability from 4kVA to 8kVA by adding modular power components. With double-conversion online architecture, hot-swappable modules, and intelligent management, it ensures maximum uptime and ease of maintenance.

Key features include a removable I/O wiring tray, network management card, and compatibility with multiple input/output voltages (220/230/240V or 380/400/415V). Ideal for mission-critical applications requiring reliable, uninterrupted power.

Category Details
Product Type Uninterruptible Power Supply (UPS)
Range APC Symmetra LX
Power Capacity 4kVA (Scalable to 8kVA) / 2800W (Max 5600W Configurable)
Input Voltage 220/230/240V single-phase, 380/400/415V three-phase
Output Voltage 220/230/240V
UPS Type Double Conversion Online
Redundancy N+1 Redundant Power Module Architecture
Runtime at Full Load 7 min 28 sec (at 2800W)
Battery Type Lead-Acid (1 filled slot, 1 free slot)
Recharge Time 3 hours
Hot-Swappable Modules Yes (Battery and Power Modules)
Mounting Tower (Not Rack-mountable)
Color Black / Silver
Dimensions (H x W x D) 67.1 x 48.3 x 72.6 cm
Weight 157.73 kg
Communication Network Management Card 2, LCD Status Console, Audible/Visual Alarms
Certifications CE, C-Tick, GOST, VDE
Conformance EN/IEC Standards (EN 60950, EN 55022, EN 50091, etc.)
Operating Temp 0 to 40 °C
Humidity 0 to 95% (non-condensing)
Altitude Limit 0 to 10,000 ft (operation)
Warranty 2 Years Repair or Replace
Included Accessories Web/SNMP Management Card, Software CD, Manuals

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries