APC Symmetra RM 6 kVA N+1 UPS w/ 208-120 V Step-Down Transformer, 10U – SYH6K6RMT-TF3

Save $6,988.01
APCSKU: SYH6K6RMT-TF3
QUANTUM Authorized
Google Top Quality Store

Price:
Sale price$13,481.99 Regular price$20,470.00
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

Keep mission-critical servers and network gear online—even when the power goes out. The APC Symmetra RM SYH6K6RMT-TF3 delivers 6 kVA / 4.2 kW of true online, double-conversion protection in a compact 10U rack chassis. N+1 modular power and battery architecture lets you hot-swap modules for zero-downtime maintenance and effortless scalability in 2 kVA increments.

A factory-integrated 208 → 120 V step-down transformer with four NEMA L5-20R outlets makes it simple to power mixed-voltage racks, while dual L6-20R receptacles serve 208 V loads. With an embedded Network Management Card 2, real-time monitoring and graceful shutdown are just a click away.

Key benefits

  • Redundant N+1 design – hot-swappable power & battery modules

  • Integrated transformer – run 120 V and 208 V equipment from one UPS

  • High efficiency – up to 85 % online; 0.98 input power factor

  • LCD & remote management – local diagnostics plus SNMP/HTTPS control

  • Scalable runtime – external XR battery frames for longer backup

Specification SYH6K6RMT-TF3 Details
Rated / Max Configurable Power 6 kVA / 4.2 kW (modular, N+1)
Topology Double-Conversion Online
Input 208 V, 60 Hz, NEMA L6-30P (10 ft cord)
Output Voltages 120 V & 208 V selectable
Primary Outlets 4 × NEMA L5-20R (120 V), 2 × NEMA L6-20R (208 V)
Transformer 208 → 120 V step-down, internal
Runtime @ Full Load (4.2 kW) ≈ 12 min 37 s (standard batteries)
Battery Modules / Type 3 × SYBT modules, sealed lead-acid; hot-swappable
Recharge Time ≤ 3 h to 90 %
Expansion Slots 1 × SmartSlot (pre-installed NMC2)
Form Factor / RU 10U rack-mount (19″)
Dimensions (H × W × D) 17.52 ″ × 19.02 ″ × 28.74 ″ (445 × 483 × 730 mm)
Weight 389.8 lb / 176.8 kg
Operating Temp / Humidity 0 – 40 °C (32 – 104 °F) / 0 – 95 % RH
Certifications UL 1778, CSA, FCC Part 15 Class A
Warranty 2-year repair or replace; optional on-site & extended plans

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries