Vertiv Liebert APS 5kVA Modular UPS | Scalable to 15kVA N+1 | 120/208V Split Phase

Save $4,307.01
VertivSKU: AS5A0NCVGNNXLKB
Vertiv Authorized
Google Top Quality Store

Price:
Sale price$10,853.99 Regular price$15,161.00
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Vertiv Liebert APS AS5A0NCVGNNXLKB is a high-performance, modular online double conversion UPS designed for mission-critical applications. Delivering 5kVA capacity and scalable to 15kVA N+1, this split-phase (120/208V) UPS provides up to 15 minutes of full-load runtime, ideal for server rooms and enterprise IT systems.

Equipped with factory-installed SNMP/Webcard (IS-UNITY-DP), it enables seamless remote management via free Power Insight software. Its rack/tower convertible form factor, hot-swappable FlexPower and battery modules, and transformer-based design offer unmatched flexibility and uptime. Energy efficiency reaches up to 92%, reducing TCO and supporting green initiatives. Fully compliant with global safety and environmental standards, this unit is new and factory fresh, backed by a 2-year limited warranty.

Specification Details
Manufacturer Vertiv
Brand Liebert
Product Line APS
Model Number AS5A0NCVGNNXLKB
UPS Topology Online Double Conversion
Scalability 5kVA to 15kVA N+1
Output Voltage 120/208V Split Phase
Input Voltage Range 120V – 280V AC
Input/Output Frequency 70 Hz Input / 60 Hz Output
Full Load Runtime 15 Minutes
Half Load Runtime 40 Minutes
Form Factor Rack/Tower Convertible
Plug/Connector Type Hard Wire 4-wire (L-L-N-G)
Communication Interfaces USB, Serial, EPO Port
Pre-Installed Card SNMP/Webcard (IS-UNITY-DP)
Free Software Trellis™ Power Insight
Battery Type Valve-Regulated Lead Acid
Battery Hot Swappable Yes
Efficiency Up to 92%
Max Charge Current 10A w/ Charger Module
Nominal Battery Voltage 144VDC
Mounting Options Rack or Tower, with casters
Humidity/Altitude 0–95% RH, up to 3000m @ 25°C
Dimensions (H x W x D) 42" x 17" x 32"
Product Condition New and Factory Fresh
Shipping Weight 1 lb. (as stated)
Certifications UL 1778, CSA, FCC, IEC/EN/AS 62040
Environmental Compliance RoHS, WEEE, REACH
Warranty

2-Year Limited Warranty

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries