Eaton 93PM 40kW Double Conversion UPS with N+1 Redundancy, No Batteries, 3 Breaker MBS, Full Communication Cards (9GC308A029E20R1)

Save $28,862.01
EatonSKU: 9GC308A029E20R1
Eaton Authorized
Google Top Quality Store

Price:
Sale price$59,752.99 Regular price$88,615.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton 93PM 40kW UPS delivers enterprise-grade power protection designed for modern data centers, healthcare systems, and mission-critical infrastructure. Built with advanced double conversion technology, this system ensures continuous, clean power with zero transfer time, safeguarding sensitive equipment from outages, surges, and power disturbances.

Engineered for scalability and long-term efficiency, this configuration features N+1 redundancy for enhanced reliability and uptime, along with a maintenance bypass system (MBS) for seamless servicing without interrupting operations. The unit includes a full suite of communication cards, enabling comprehensive monitoring, remote management, and integration into existing infrastructure.

With no internal batteries, the system is optimized for external battery configurations, including lithium-ion solutions that reduce footprint and extend lifecycle performance. Flexible airflow options and a compact tower design allow for efficient deployment in a wide range of environments, helping reduce cooling costs and maximize space utilization.

Specification Details
Manufacturer Eaton
Model 93PM
SKU 9GC308A029E20R1
Power Capacity 40 kW
UPS Technology Double Conversion Online
Form Factor Tower
Redundancy N+1 Redundancy Configuration
Battery Configuration No Internal Batteries (Supports External Battery Systems)
Maintenance Bypass Integrated 3 Breaker Maintenance Bypass System (MBS)
Communication Full Communication Card Suite Included
Circuit Protection Integrated Circuit Breaker
Input/Output Voltage 208V Class (Typical for this configuration)
Cooling Options Front-to-Back or Front-to-Top Airflow
Expandability Supports external battery cabinets, parallel systems, and power distribution modules
Deployment Environment Data centers, healthcare facilities, enterprise IT, industrial applications
Height 74 inches
Depth 42 inches
Efficiency Design Optimized for reduced energy consumption and cooling costs
UNSPSC Code 39121011

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries