Eaton ePDU G3 Metered Outlet Rack PDU, 0U Vertical, 3-Phase, L21-30P, 24A, 39×C13 & 6×C19 Outlets, 6 ft Cord – EMOCPD36JE2J3B2

Save $594.01
EatonSKU: EMOCPD36JE2J3B2
Eaton Authorized
Google Top Quality Store

Price:
Sale price$2,876.99 Regular price$3,471.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton EMOCPD36JE2J3B2 is an ePDU G3 Metered Outlet (MO) Rack Power Distribution Unit engineered to provide reliable power distribution and outlet-level power monitoring for enterprise data centers, network closets, and mission-critical IT environments. Its vertical 0U form factor conserves valuable rack space while delivering power to a wide range of rack-mounted equipment.

Designed for high-density installations, this PDU features a 24A, 120/208V three-phase input with an L21-30P plug and a 6-foot attached power cord. With 39 IEC C13 outlets and 6 IEC C19 outlets, it supports servers, storage systems, networking hardware, and other rack equipment with mixed power requirements.

Outlet-level metering enables administrators to monitor power consumption, optimize load balancing, improve energy efficiency, and plan capacity with greater accuracy. Eaton's ePDU G3 platform is built for dependable performance, helping reduce downtime while simplifying power management in modern IT infrastructures.

Key Features

  • Metered Outlet (MO) intelligent rack PDU
  • Space-saving 0U vertical mounting
  • 24A, 120/208V, three-phase operation
  • L21-30P input plug with 6 ft attached cord
  • 39 × IEC C13 outlets
  • 6 × IEC C19 outlets
  • Outlet-level power monitoring
  • Ideal for enterprise servers, storage, networking, and data center applications
  • Durable Eaton construction for continuous operation
Specification Details
Brand Eaton
SKU EMOCPD36JE2J3B2
Product Series ePDU G3
Product Type Metered Outlet Rack PDU
Mounting Vertical 0U
Input Voltage 120/208V AC
Phase Three-Phase
Input Current 24A
Input Plug NEMA L21-30P
Cord Length 6 ft
Outlet Quantity 45 Total
IEC C13 Outlets 39
IEC C19 Outlets 6
Monitoring Outlet-Level Metering
Application Data Centers, Enterprise IT, Server Racks, Network Cabinets
Color Black

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries