Eaton SmartRack Modular Data Center – 2x 44U Racks, 25 kW Cooling, Service Enclosure

Save $43,667.76
EatonSKU: SRP-2R-C25-M
Eaton Authorized
Google Top Quality Store

Price:
Sale price$97,425.99 Regular price$141,093.75
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton SmartRack SRP-2R-C25-M is a pre-configured, self-cooling modular data center solution that integrates two 44U IT rack enclosures, a 25 kW in-row precision cooling unit, and a customizable service enclosure. Designed for fast deployment and edge scalability, it forms a high-efficiency closed-loop POD (performance-optimized data center) ideal for edge computing, AI/ML workloads, and industrial environments.

With robust cooling, IP54-rated protection, and customizable service options, this system helps minimize deployment time and maximize uptime. It includes locking doors with clear monitoring windows, in-rack cable and airflow management, and user-friendly controls via a 7” touchscreen and remote monitoring through WEBCARDLXMINI.

Category Details
Model Number SRP-2R-C25-M
Rack Enclosures 2 x 44U (with locking doors and clear acrylic windows)
Cooling Unit 25.8 kW (SRCOOLDXRW25), In-row DX, R410A refrigerant
Service Enclosure 800mm wide, vented doors, customizable
Cooling Capacity 88,000 BTU/hr
Airflow 2,950 CFM
User Interface 7-inch color touchscreen, WEBCARDLXMINI remote access
Voltage Compatibility 208V, 3-wire / 4-wire + Ground, 60 Hz
Dimensions (H x W x D) 95.07 x 95.98 x 64.88 in (241.48 x 243.79 x 164.80 cm)
Unit Weight 1,248.74 kg (2,753 lbs)
Max Device Depth 48.7 in (1237 mm)
Sound Level <68 dBA
IP Rating IP54
Compressor Type Rotary, Inverter-Driven
Condensate Drain 9 L/hr per unit, with integrated drain
Operating Temp. Range 64° to 104°F (18° to 40°C)
Storage Temp. Range -40° to 140°F (-40° to 60°C)
Humidity Range 5% to 80% RH
Mounting & Transport Pre-installed casters; flatbed transport-ready
Compliance FCC Part 15 Class A, RoHS
Warranty 5 years (rack/enclosure), 1 year (cooling unit)

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries