Eaton SmartRack SRP-2R-2C12 Modular Data Center – 2x 44U Racks, 2x 12 kW AC Units

Save $38,579.16
EatonSKU: SRP-2R-2C12
Eaton Authorized
Google Top Quality Store

Price:
Sale price$64,121.99 Regular price$102,701.15
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton SmartRack SRP-2R-2C12 is a pre-configured, self-cooling modular data center designed to simplify deployment, lower costs, and meet the demands of edge computing and AI workloads. This performance-optimized data center (POD) includes two 44U IT rack enclosures and two 12 kW in-row cooling units (SRCOOLDXRW12), forming a compact closed-loop system that delivers efficient precision cooling in a secure, scalable format.

Ideal for factories, warehouses, and distributed sites, the SRP-2R-2C12 protects equipment from physical and environmental stress with its locking doors, moisture-isolated cable routing, and IP54-rated design. The entire system arrives preassembled with casters for easy positioning and includes user-friendly touchscreen interfaces and remote monitoring capabilities.

Specification Details
Model Number SRP-2R-2C12
Rack Capacity 2x 44U Enclosures (88U total)
Cooling Units 2x 12 kW In-Row Cooling Units (SRCOOLDXRW12)
Cooling Type Direct Expansion (DX), Active Cooling
Cooling Capacity 25.6 kW / 87,372 BTU
Airflow 2,950 CFM
Refrigerant R410A
Compressor Rotary (Inverter Driven)
Display Interface 7" Color Touchscreen + WEBCARDLXMINI (Remote Access)
Ingress Protection (IP) IP54
Noise Level < 68 dBA
Casters Pre-installed for mobility
Dimensions (H x W x D) 95.07 x 81.02 x 64.88 in (241.48 x 205.79 x 164.80 cm)
Weight (Total) 2,814 lbs (1,276.41 kg)
Weight Capacity (Stationary) 3,000 lbs (1,361 kg)
Operating Temp 64°F to 104°F (18°C to 40°C)
Storage Temp -40°F to 140°F (-40°C to 60°C)
Humidity Range 5% to 80% RH
Elevation (Operating) Up to 13,123 ft (4,000 m)
Condensate Drain Pumps 9 L/hr per unit
Certifications FCC Part 15 Class A (USA), RoHS
Warranty 1-Year (Cooling Units), 5-Year (Rack Enclosures)

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries