The Tripp Lite by Eaton PDUMNH20HVAT is a high-availability, single-phase monitored automatic transfer switch (ATS) PDU designed to provide redundant power and continuous uptime for critical IT equipment. Delivering up to 3.8kW at 208/240V, this 1U rack-mount PDU is ideal for data centers, server rooms, and network closets supporting non-redundant power supply devices.

Equipped with dual L6-20P input plugs, the PDUMNH20HVAT continuously evaluates both power sources and performs automatic solid-state transfer switching within 1–5 milliseconds to prevent downtime during power interruptions or instability. A single L6-20R output supports direct connection to mission-critical equipment or downstream PDUs.

The built-in LX Platform HTML5 network interface enables real-time remote power monitoring without Java, supporting secure browser access, SNMP, SSH, and email alerts. Optional EnviroSense2 modules expand monitoring to include environmental conditions such as temperature and humidity. With TAA compliance, RoHS certification, and a compact 1U horizontal rack design, the PDUMNH20HVAT is a dependable solution for enterprise and government IT environments requiring resilient power infrastructure.

Category Specification
Brand Tripp Lite by Eaton
Manufacturer Part Number PDUMNH20HVAT
Product Type Monitored ATS PDU
Power Rating 3.8 kW
Phase Single-Phase
Input Voltage 208 / 240V AC
Output Voltage 208 / 240V AC
Input Current 20A
Input Connections 2 × NEMA L6-20P (10 ft cords)
Output Receptacles 1 × NEMA L6-20R
Transfer Time 1–5 milliseconds
Monitoring Interface LX Platform (HTML5, Java-free)
Network Connectivity 10/100 Mbps Ethernet
Supported Protocols IPv4, IPv6, HTTP/HTTPS, SNMP v1/v2/v3, SSH, Telnet, SMTP, FTP, DHCP, NTP
Mounting Orientation Horizontal
Rack Height 1U
Rack Compatibility Standard 19-inch EIA racks
Dimensions (H × W × D) 1.7" × 16.9" × 14"
Weight Approx. 15.37 lb
Country of Origin Taiwan
TAA Compliant Yes
Environmental Compliance RoHS
Warranty 2-Year Limited
Package Contents PDU, mounting brackets, owner’s manual

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements