The Eaton Tripp Lite SR42UBWDSP1 is a 42U SmartRack enclosure engineered for high-density applications, offering an extra-wide (750mm) and standard-depth (1050mm) cabinet structure. Designed with reinforced shock-absorbing packaging for safe re-shipping, it supports up to 3500 lbs of stationary equipment and 2250 lbs while rolling. The enclosure includes locking front/rear doors and side panels, preinstalled casters, and leveling feet for mobility and stability. Its open-frame ventilation, tool-less top panel, and vertical cable management rails make it ideal for optimized airflow and organized data center installations. Ships fully assembled with accessories for rapid deployment.

Specification Details
Model Number SR42UBWDSP1
Rack Height 42U
Rack Width / Depth 30" (750mm) Wide / 42" (1050mm) Standard-Depth
Max Device Depth 37 in. (94 cm)
Min Device Depth 4 in. (10.16 cm)
Weight Capacity (Stationary / Rolling) 3500 lbs (1588 kg) / 2250 lbs (1020.6 kg)
Shipping Weight / Dimensions 390 lbs (176.9 kg) / 85" x 31.5" x 45" (216 x 80 x 114 cm)
Unit Weight / Dimensions 315 lbs (142.88 kg) / 78.5" x 29.63" x 43" (199 x 75 x 109 cm)
Mounting Rails 4 vertical posts, square hole, adjustable in 1/4" increments
Casters & Levelers Pre-installed heavy-duty casters and removable levelers
Doors & Side Panels Locking, removable, reversible; keyed alike
Ventilation 65%+ open perforation for airflow; vented top panel
Cable Management Built-in vertical rails; open bottom and top panel cable access
Grounding Integrated grounding points; quick-release ground wires
Standards Compliance PCI DSS compliant; UKCA
Warranty 5-year limited warranty
Included Accessories Ramps, keys, M6 cage nuts/screws/washers, side panels, owner's manual
UPC Code 037332175373
Compatibility Patch Panels, Network Switches, UPS, Servers

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some productsβ€”such as custom orders, special-order items, audio gear, software, and LED video wallsβ€”are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more β†’

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments β€” from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery β€” trusted by 275+ clients across industries