Eaton Tripp Lite SR48UBSP1 48U SmartRack Standard-Depth Rack Enclosure with Doors, Side Panels & Shock Pallet Packaging

Save $1,440.99
EatonSKU: SR48UBSP1
Eaton Authorized
Google Top Quality Store

Price:
Sale price$2,535.99 Regular price$3,976.98

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton Tripp Lite SR48UBSP1 is a 48U SmartRack standard-depth rack enclosure designed for secure, high-density server and networking installations. It ships fully assembled on a reinforced shock pallet with loading ramps, making it ideal for pre-configuration, safe transport, and re-shipping to remote installation sites.

Built for data centers, IT rooms, and enterprise environments, this rack supports EIA-310-D compliant 19-inch equipment and includes locking removable doors, keyed side panels, adjustable mounting rails, heavy-duty casters, and front-to-rear airflow ventilation. With a 3,500 lb stationary load capacity and 2,250 lb rolling capacity, it provides dependable support for servers, UPS systems, PDUs, switches, KVMs, and other critical infrastructure.

Specification Details
Brand Eaton Tripp Lite
SKU SR48UBSP1
Product Type Rack Enclosure Cabinet
Rack Height 48U
Rack Width 24 in.
Rack Depth Standard Depth
Color Black
Rack Compatibility EIA-310-D compliant 19 in. equipment
Device Compatibility Servers, UPS systems, network switches, patch panels, PDUs, KVMs
Maximum Device Depth 37 in. / 940 mm
Minimum Device Depth 4 in. / 102 mm
Factory Preset Rack Depth 27.75 in. / 705 mm
Unit Dimensions 89.00 x 23.63 x 43.00 in.
Shipping Dimensions 95.00 x 26.00 x 45.00 in.
Unit Weight 315 lb / 142.88 kg
Shipping Weight 403 lb / 182.80 kg
Stationary Load Capacity 3,500 lb / 1,588 kg
Rolling Load Capacity 2,250 lb / 1,021 kg
Shock Pallet Capacity Up to 1,250 lb total shipping load
Doors Locking, removable, reversible front and rear doors
Side Panels Locking, removable side panels
Mounting Rails 4 vertical mounting rails
Casters Pre-installed heavy-duty casters
Ventilation Perforated front and rear doors for front-to-rear airflow
Cable Access Open bottom and removable top panel with cable access holes
Grounding Front and rear door frame grounding
Certifications UL 60950-1
Compliance RoHS, CE, UKCA
Warranty 5-year limited warranty

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some productsβ€”such as custom orders, special-order items, audio gear, software, and LED video wallsβ€”are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more β†’

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments β€” from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery β€” trusted by 275+ clients across industries