Eaton Tripp Lite Medical-Grade Isolation Transformer 1800W Dual Voltage 115/230V 8 C13 Outlets (IS1800HGDV)

Save $874.29
EatonSKU: IS1800HGDV
HPE Authorized
Google Top Quality Store

Price:
Sale price$1,498.99 Regular price$2,373.28
For purchases above $5,000, please request a formal quote. Orders are payable via Wire Transfer only. Quotes include lead time and shipping. Leasing and financing available for qualified business customers.

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton Tripp Lite IS1800HGDV medical-grade isolation transformer delivers reliable power conditioning and complete electrical isolation for sensitive equipment in healthcare, laboratory, industrial, and IT environments. Designed to meet IEC 60601-1 standards, this unit minimizes leakage current and protects connected devices from EMI/RFI interference, surges, and line noise.

With dual-voltage support (115V/230V) and flexible step-up or step-down capability, the IS1800HGDV adapts to a wide range of deployment scenarios. Its low-impedance toroidal design ensures efficient operation with up to 96% efficiency, while built-in overload protection enhances safety by automatically shutting down outputs during fault conditions.

Engineered for mission-critical applications, this transformer features eight C13 outlets, robust metal housing, and advanced noise suppression, making it ideal for powering medical devices, network infrastructure, and precision electronics requiring clean and stable power.

Specification Details
Brand Eaton Tripp Lite
Product Type Medical-Grade Isolation Transformer
Model / Catalog Number IS1800HGDV
Power Capacity 1800W / 1800 VA
Input Voltage 115/230 VAC (Selectable via fuse installation)
Output Voltage 115/230 VAC (Selectable; step-up or step-down capable)
Frequency 50/60 Hz
Input Current 15A @ 115V / 8A @ 230V
Output Regulation 3.6%
Efficiency 96%
Leakage Current ≀ 80 Β΅A
Surge Suppression 240 Joules
Maximum Surge Current 100A
Noise Suppression 35–65 dB EMI/RFI filtering
Transformer Type Low Impedance Toroidal Isolation Transformer
Outlets 8 x C13
Input Connector IEC-320-C20
Overcurrent Protection Dual fuses (115V and 230V included)
Cooling Method Convection
Operating Temperature 32Β°F to 104Β°F (0Β°C to 40Β°C)
Storage Temperature 5Β°F to 122Β°F (-15Β°C to 50Β°C)
Humidity 5% to 95% (non-condensing)
Operating Elevation Up to 10,000 ft (3000 m)
Enclosure Metal Cabinet
Color White
Certifications IEC 60601-1, CSA, NOM
Compliance CE, RoHS, TAA Compliant
Dimensions (H x W x D) 11.02 x 17.52 x 19.69 in
Weight 51.21 lb
Included Accessories Fuse sets (115V & 230V), cable selector sheet, owner’s manual

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some productsβ€”such as custom orders, special-order items, audio gear, software, and LED video wallsβ€”are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more β†’

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments β€” from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery β€” trusted by 275+ clients across industries