Description
The Eaton Tripp Lite SmartPro SMART3000RM2U is a 3000VA/3000W line-interactive UPS designed to deliver reliable, pure sine wave power protection for servers, VoIP systems, data storage, and networking devices. With a unity power factor, it maximizes usable power for connected equipment, ensuring consistent uptime in demanding IT, telecom, and enterprise environments.
This 2U rack/tower UPS provides automatic voltage regulation (AVR) to correct under- and over-voltage conditions without draining the battery. Its hot-swappable, field-replaceable VRLA batteries offer up to 9 minutes of runtime at half load, allowing safe system shutdown during extended outages.
Equipped with six NEMA 5-20R outlets and one L5-30R outlet, the SMART3000RM2U ensures clean, filtered power distribution across critical loads. Two independently controllable outlet banks support load shedding to extend runtime. The intuitive LCD display with 10 selectable screens provides real-time system data, while USB, DB9, and optional network card ports (WEBCARDLXE) enable local or remote monitoring and management.
Built with ENERGY STAR qualification, high efficiency (98%), and surge/noise protection, this UPS safeguards against power disturbances that threaten data integrity and hardware performance.
Ideal for high-end desktop, small network, or large enterprise installations, the SMART3000RM2U combines reliable backup power with advanced control and protection features in a compact, flexible form factor.
| Category | Specification |
|---|---|
| Model Number | SMART3000RM2U |
| Type | Line-Interactive UPS |
| Capacity | 3000VA / 3000W |
| Power Factor | 1.0 (Unity) |
| Input Voltage | 120V AC (80–151V adjustable to 70–153V) |
| Input Connection | NEMA L5-30P |
| Input Cord Length | 10 ft (3.1 m) |
| Output Voltage | 100V / 110V / 120V / 125V |
| Output Waveform | Pure Sine Wave |
| Output Receptacles | (6) NEMA 5-20R, (1) NEMA L5-30R |
| Load Management | Two independently switchable outlet banks |
| Voltage Regulation (AVR) | Corrects 81–150V to regulated 120V |
| Transfer Time | 1–4 ms |
| Battery Type | Valve-Regulated Lead Acid (VRLA), hot-swappable |
| Runtime (Half Load) | 9 minutes (1500W) |
| Recharge Time | <5 hours (10–90%) |
| Communications Ports | USB, DB9 Serial, EPO, Dry Contact, SNMP Slot |
| Network Management | Optional WEBCARDLXE (not compatible with WEBCARDLX) |
| Display | 2-line LCD with 10 selectable monitoring screens |
| Form Factor | 2U Rackmount / Tower |
| Dimensions (H × W × D) | 3.4 × 17.2 × 23.7 in (8.64 × 43.69 × 60.20 cm) |
| Weight | 74.5 lbs (33.79 kg) |
| Cooling | Dual fan system |
| Noise Level | 50 dBA (max at 1m front) |
| Operating Temperature | 32°F – 104°F (0°C – 40°C) |
| Efficiency (AC Mode) | 98% |
| Certifications | UL 1778, ENERGY STAR, FCC Class A, RoHS, CAN/CSA-C22.2 |
| Warranty | 2 years standard (3 years with registration) |
| Connected Equipment Insurance | $250,000 (U.S., Canada & Puerto Rico) |
Payment & Security
Your payment information is processed securely, and we do not store credit card details or access your credit card information.
Return Policy (Short Summary)
We offer a 30-day return window for most unopened, factory-sealed items.
Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.
Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.
For damaged or incorrect items, please contact us immediately.
From Scope to Sign-Off
A structured delivery process designed to reduce risk and keep projects moving.
Plan
Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.
- Discovery calls & stakeholder interviews
- On-site survey & infrastructure review
- Requirements & use-case documentation
- Project scope, timeline & milestone alignment
Engineer
System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.
- AV system design & signal flow diagrams
- Equipment selection & BOM development
- Rack layout & control system design
- As-built documentation package
Deploy
Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.
- Authorized procurement & logistics coordination
- Physical installation & cable management
- Control system programming & configuration
- Commissioning, testing & end-user training
Support
Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.
- 24/7 remote system monitoring
- Preventive & reactive maintenance
- Technology lifecycle & refresh planning
- Long-term service level agreements
A decade of delivery — trusted by 275+ clients across industries
