Eaton Tripp Lite PDU3EVSR10L2130 10kW 3-Phase Switched PDU with LX Interface, 30 Outlets, L21-30P, 0U Vertical Mount

Save $1,108.01
EatonSKU: PDU3EVSR10L2130
Eaton Authorized
Google Top Quality Store

Price:
Sale price$1,949.99 Regular price$3,058.00

Shipping calculated at checkout

Stock:
In stock (10 units), ready to be shipped

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Eaton Tripp Lite PDU3EVSR10L2130 is a high-performance 10 kW 200–240 V 3-phase switched rack PDU designed for advanced power distribution, monitoring, and control in data centers and enterprise network environments. Featuring 30 switched outlets (24 Γ— C13, 6 Γ— C19) and a NEMA L21-30P input plug with a 3 m power cord, it provides exceptional flexibility for managing connected equipment.

The built-in Gigabit LX Platform interface (WEBCARDLX) with HTML5-based PowerAlert Device Manager (PADM20) allows secure, Java-free remote management via HTTPS, SNMP, SSH, or Telnet. Users can control, reboot, or lock out individual outlets remotely, enabling proactive load management and reduced downtime.

A vibrant color touchscreen LCD delivers Β±1 % billing-grade accuracy for monitoring per-phase and per-outlet current, wattage, and voltage. The unit also generates a QR code for quick mobile access and integrates with optional EnviroSense2 environmental sensors. Constructed from durable metal, the 0U vertical-mount PDU fits standard EIA 19-inch racks and is TAA compliant, making it ideal for government or enterprise deployments requiring precise, network-grade power management.

Category Specification
Model Number PDU3EVSR10L2130
Power Capacity 10 kW (240 V), 9.6 kW (230 V), 9.1 kW (220 V), 8.6 kW (208 V), 8.3 kW (200 V)
Input Type NEMA L21-30P, 3-Phase, 200–240 V AC
Input Cord Length 10 ft (3.05 m)
Maximum Input Current 24 A (agency-derated continuous)
Output Outlets 30 total (24 Γ— C13, 6 Γ— C19)
Output Voltage 200–240 V AC
Overload Protection Three Γ— 20 A circuit breakers (one per load bank)
Monitoring Accuracy Β±1 % (billing-grade for Amps/Volts/Watts)
Network Interface Pre-installed WEBCARDLX (Gigabit Ethernet) with PADM20
Supported Protocols IPv4/IPv6, HTTP/HTTPS, SNMP (v1/v2c/v3), SSH, Telnet, FTP, DHCP, NTP
Display Color touchscreen LCD with QR code mobile access
Communications Ports 1 Γ— RJ-45 (network), 1 Γ— RJ-45 (config), 2 Γ— USB-A (for EnviroSense2 modules), 1 Γ— USB-B (config console)
Material Heavy-duty metal enclosure
Mounting Type 0U vertical rackmount (with brackets and tool-less buttons)
Rack Height 0U (1.8 m tall)
Dimensions (H Γ— W Γ— D) 70 Γ— 2.17 Γ— 2.86 in (177.8 Γ— 5.5 Γ— 7.3 cm)
Weight 20.01 lb (9.08 kg)
Operating Temperature 0 – 50 Β°C (32 – 122 Β°F)
Relative Humidity 5 – 95 % non-condensing
Compliance UL 60950-1, CSA, NOM, FCC Part 15 Class A, RoHS, TAA
Warranty 2-Year Limited Warranty

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some productsβ€”such as custom orders, special-order items, audio gear, software, and LED video wallsβ€”are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more β†’

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments β€” from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery β€” trusted by 275+ clients across industries