Server Technology PRO2 C2SG48TE-DQME2M99 48-Outlets Smart POPS PDU

Server Technology, IncSKU: C2SG48TE-DQME2M99
Google Top Quality Store

Price:
Sale price$4,111.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Server Technology® PRO2 C2SG48TE-DQME2M99 Smart POPS PDU (Primary) delivers advanced power monitoring and distribution for high-density data centers. Featuring 48 outlets (30 x C13, 18 x Cx hybrid), this three-phase intelligent PDU combines Per Inlet Power Sensing (PIPS®) and Per Outlet Power Sensing (POPS®) technologies for billing-grade accurate measurements of current, voltage, power, and energy at both the input and outlet levels.

Designed for resilience and flexibility, the unit supports Star Multi-Linking to connect up to four circuits with a single IP address, while hot-swap network cards maintain uptime. With comprehensive environmental monitoring, alternating-phase outlets for simplified load balancing, and compliance with UL 62368-1 and IEC 62368-1 safety standards, the C2SG48TE ensures reliable and efficient power distribution in demanding environments up to 60°C.

Ideal for enterprises seeking maximum visibility, high availability, and intelligent control of rack-level power distribution.

Category Details
Manufacturer Server Technology, a brand of Legrand
Product Series PRO2 Smart POPS
Model / SKU C2SG48TE-DQME2M99 (Primary)
Outlets 48 total (30 x IEC C13, 18 x Cx hybrid C13/C19)
Input Voltage 208V, 50/60 Hz
Input Plug 208V Delta 60A IEC 60309 3P+G (9Hr)
Input Current Rated 48A
Power Capacity 17.3 kW
Circuit Protection 6 x 20A UL 489 circuit breakers (2-pole, 16A rating, 10 kAIC)
Monitoring PIPS® (per inlet), POPS® (per outlet), branch current monitoring
Network Access HTTP(S), SSH, Telnet, SNMPv2/v3, Syslog, LDAP(S), SMTP, FTP/SFTP, RS-232 serial
Connectivity 10/100/1000 Mbps Ethernet (RJ-45), IPv4/IPv6
Environmental Sensors Supports 2 external temp/humidity probes, SNMP/email alerts
Physical Dimensions 80.0" H × 2.2" W × 2.5" D (2032 × 56 × 64 mm)
Operating Temp 0°C to 60°C (32°F to 140°F)
Certifications UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, CAN ICES-003 Class A
Warranty 2-year limited (parts & labor)
Optional Accessories Temp/humidity probes (EMTH-2-10), EMCU-1-1C Env. Monitor, PRO2 Link Kits, cable retention devices

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries