Server Technology PRO2 C2W36TE-2QAF2M99 36-Outlets Switched PDU

Save $115.00
Server Technology, IncSKU: C2W36TE-2QAF2M99
Google Top Quality Store

Price:
Sale price$3,161.00 Regular price$3,276.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Server Technology® PRO2 C2W36TE-2QAF2M99 Switched PDU delivers intelligent power distribution and advanced monitoring capabilities for high-density data centers. Equipped with HDOT Cx outlets, it supports both C14 and C20 plugs, ensuring flexibility and future-ready compatibility. With integrated PIPS® technology, it provides billing-grade measurement of current, voltage, power, and energy per inlet, while branch circuit monitoring adds protection against overloads.

Featuring network-based monitoring, hot-swappable network cards, and the ability to link up to four PDUs using a single IP address, this unit ensures maximum uptime and redundancy. SNMP-based alerts, environmental monitoring, and outlet-level power control make it an essential solution for reliable, efficient, and scalable rack power management.

Ideal for enterprise-class data centers, the PRO2 Switched PDU supports 60A input, provides 36 outlets (18x C13, 18x Cx), and operates safely in demanding environments up to 60 °C.

Category Details
Manufacturer Server Technology, a brand of Legrand
Product Line PRO2 Switched PDU
Model / SKU C2W36TE-2QAF2M99 (Primary)
Outlets 36 total (18 × IEC 60320 C13, 18 × HDOT Cx hybrid outlets)
Input Plug / Voltage IEC 208V/60A 2P+G 6Hr, 208V, 50/60Hz
Input Current 60A (rated 48A)
Power Capacity 10 kW
Outlet Rating C13: ≤12A @208V (15A peak) Cx: ≤16A @208V (20A peak)
Branch Circuit Protection 3 × 20A 2-pole magnetic-hydraulic circuit breakers, UL 489 compliant
Monitoring Technology PIPS® per inlet power sensing; branch circuit monitoring; LED auto-flip display
Control Features Outlet switching (on/off, reboot per outlet/group)
Network Interfaces HTTP(S), SSH, Telnet, SNMPv2c/v3, Syslog, LDAP(S), TACACS+, RADIUS, FTP/SFTP
Sensors Supported 2 × external temp/humidity probes (optional accessories available)
Physical Dimensions 70.0 in (H) × 2.2 in (W) × 2.5 in (D) (1778 × 56 × 64 mm)
Operating Temperature 32°F to 140°F (0°C to 60°C)
Certifications UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, CAN ICES-003 Class A
Warranty 2-Year Limited Parts & Labor (extendable)
Country of Origin United States

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries