Server Technology PRO3X C3WG36RL-DQJE2MT2 36-Outlets Switched POPS PDU

Server Technology, IncSKU: C3WG36RL-DQJE2MT2
Google Top Quality Store

Price:
Sale price$3,089.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Server Technology® PRO3X Switched POPS PDU (C3WG36RL-DQJE2MT2) delivers next-generation power distribution and monitoring for demanding data center environments. Built on the advanced Xerus Technology Platform, it combines PIPS® (Per Inlet Power Sensing) and POPS® (Per Outlet Power Sensing) for precise billing-grade measurement of power metrics at every level—inlet, outlet, and branch circuit.

Equipped with HDOT Cx outlets, this PDU supports both C14 and C20 plugs, offering maximum flexibility. The RamLock locking mechanism ensures reliable connections, while multi-unit linking and cascading simplifies management with up to 16 PDUs controlled via a single IP. The multi-color LCD, hot-swappable controller, and robust environmental monitoring (temperature, humidity, airflow, water, dry contact, etc.) make it ideal for mission-critical operations.

With outlet-level switching, administrators can remotely cycle power to outlets for server reboots or disable unused receptacles. Designed for durability, it supports safe operation in 60°C environments, includes flexible mounting options, and complies with UL/IEC 62368-1 safety standards.

Category Details
Manufacturer Server Technology (Legrand Group)
Product Line PRO3X
Model / Part Number C3WG36RL-DQJE2MT2
Product Type Switched POPS PDU
Input Voltage 208V, 50/60Hz
Input Plug IEC 60309, 3P+G, 60A, 9Hr
Input Current (Rated/Max) 48A / 60A
Input Power Capacity 17.3 kW
Outlets 18 × IEC C13 (≤12A @208V L-L) 18 × HDOT Cx (≤16A @208V L-L)
Outlet Features RamLock locking, Outlet-level switching
Branch Circuit Protection (6) 2-pole, 20A UL 489 breakers, 10 kAIC
Monitoring PIPS® (inlet) + POPS® (outlet) + Branch current monitoring
Communications Dual Gigabit Ethernet, RS-232, USB-A/B, Wi-Fi (optional)
Protocols Supported HTTP/HTTPS, SSH, Telnet, SNMP v2/v3, Syslog, LDAP(S), RADIUS, FTP/SFTP
Environmental Sensors Supports up to 12 Legrand DX2 SmartSensors
Operating Temp 32°F to 140°F (0°C to 60°C)
Dimensions (HxWxD) 70.0 × 2.2 × 2.5 in (1778 × 56 × 64 mm)
Weight [Refer to datasheet if required]
Certifications UL 62368-1, CSA 62368-1, FCC Class A, CAN ICES-003 Class A
Country of Origin United States
Warranty Standard 2-year limited; extended support available

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries