The Server Technology PRO4X Smart PDU (C4S36RA-DQBD2FE1) delivers advanced rack power distribution with intelligent monitoring, environmental sensing, and secure remote access. Built on the cutting-edge Xerus platform, this PDU provides precise per-inlet power sensing, waveform capture, and branch circuit protection for mission-critical environments. Featuring HDOT Cx hybrid outlets (supporting both C13 and C19 plugs), RamLock self-locking technology, and a 45° angled infeed for strain relief, it ensures safe, reliable connectivity in high-density data centers.

With support for cascading up to 16 PDUs under a single IP, strong encryption, SNMP alerts, and environmental monitoring through Legrand DX2 SmartSensors, this PDU combines efficiency, scalability, and security. Its hot-swappable controller, RGB LED outlet indicators, and multi-color LCD provide clear visibility and simplified management, making it the ideal choice for modern data center infrastructure.

Category Details
Manufacturer Server Technology (Legrand Group)
Product Line PRO4X Smart PDU
Model / SKU C4S36RA-DQBD2FE1
Form Factor Vertical (70.0 in x 2.2 in x 2.5 in)
Input Voltage 208V, 50/60 Hz
Input Plug 208V Delta 60A IEC 60309 3P+G 9Hr
Input Current 60A (rated 48A)
Power Capacity 17.3 kW
Outlets (24) HDOT Cx (≤16A @208V L-L), (12) IEC C13 (≤12A @208V L-L)
Outlet Features HDOT Cx hybrid (C13/C19), RamLock secure locking, RGB LED indicators
Monitoring Per-Inlet Power Sensing (PIPS®), waveform capture, power quality measurements
Networking & Security HTTP/HTTPS, SSH, SNMP v2/v3, LDAP(S), RADIUS, TACACS+, IPv4/IPv6, dual Ethernet, optional Wi-Fi
Environmental Support Up to 12 DX2-series SmartSensors (temp, humidity, airflow, leak, vibration, etc.)
Branch Circuit Protection UL 489 2-pole, 20A breakers (≤16A per branch)
Operating Temp. 0°C to 60°C (32°F to 140°F)
Storage Temp. -30°C to 80°C (-22°F to 176°F)
Certifications UL 62368-1, CSA C22.2, FCC Part 15, ICES-003 Class A
Warranty 2-Year Limited (Extended options available)
Additional Features Hot-swappable controller, alternating-phase outlets, flexible mounting, multi-unit linking (up to 16 PDUs)

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries