Server Technology PRO4X C4W36RA-DFBD2FE1 36-Outlets Switched PDU

Save $1.00
Server Technology, IncSKU: C4W36RA-DFBD2FE1
Google Top Quality Store

Price:
Sale price$3,621.00 Regular price$3,622.00

Shipping calculated at checkout

Stock:
Only 0 units left

Need this as part of a larger AV project? AVENDOR can help with sourcing, installation, support, and monthly payment options

Description

The Server Technology® PRO4X C4W36RA-DFBD2FE1 Switched PDU delivers intelligent power distribution for modern data centers. Powered by the advanced Xerus network interface, it provides remote access to power metrics, outlet-level control, and environmental monitoring.

Designed for resilience and scalability, this 36-outlet PDU features HDOT Cx outlets that accept both C14 and C20 plugs, RamLock locking outlets for secure connections, and a 45° angled infeed for improved cable management. With multi-unit linking and cascading, up to 16 PDUs can be managed under one IP, while per-inlet power sensing and waveform capture deliver highly accurate power quality insights.

Enhanced security includes 256-bit AES encryption, SSH, SSL, HTTPS, Active Directory integration, and SNMPv3 support. A multi-color LCD, RGB LED outlet indicators, and branch circuit protection ensure reliability. Rated for operation in 60°C environments, it is ideal for mission-critical IT infrastructures that demand maximum uptime, safety, and monitoring.

Category Details
Manufacturer Server Technology (Legrand)
Product Line PRO4X Switched PDU
Model / SKU C4W36RA-DFBD2FE1
Outlets 36 total (12 × IEC C13, 24 × HDOT Cx hybrid C13/C19)
Outlet Features HDOT Cx hybrid design, RGB LED indicators, RamLock locking outlets
Input Voltage 208V, 50/60Hz
Input Plug CS8365 3P+G 50A
Input Current 50A (Rated 40A)
Power Capacity 14.4 kW
Branch Protection UL 489 2-pole, 20A breakers (6 branches, ≤16A each)
Monitoring & Control Outlet-level switching, per-inlet power sensing (PIPS®), waveform capture
Networking & Security Dual Ethernet, SSH, HTTPS, SNMPv3, LDAP/LDAPS, RADIUS, TACACS+
Multi-Unit Linking Up to 16 PDUs daisy-chained per IP
Display Multi-color LCD with power usage, alarms, and alerts
Environmental Sensors Supports up to 12 daisy-chained Legrand DX2 SmartSensors
Operating Temp 0–60 °C (32–140 °F)
Dimensions 70.0 × 2.2 × 2.5 in (1778 × 56 × 64 mm)
Certifications UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Class A, CAN ICES-003 Class A
Warranty 2-Year Limited (extended options available)

Payment & Security

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely, and we do not store credit card details or access your credit card information.

Return Policy (Short Summary)

We offer a 30-day return window for most unopened, factory-sealed items.

Returns must be authorized before shipping back and must include all original packaging and accessories. Opened or used items are not returnable unless defective.


Some products—such as custom orders, special-order items, audio gear, software, and LED video walls—are non-returnable. Non-defective returns may be subject to a 20–30% restocking fee, and customers are responsible for return shipping costs.


For damaged or incorrect items, please contact us immediately.


Learn more →

275+
Projects Delivered
<2h
Avg Response Time
99.9%
System Uptime
10+
Years in AV
Complete AV Solutions

Building a Complete AV System?

This product is rarely deployed alone. It's typically part of a fully integrated AV system. AVENDOR designs, integrates, and supports end-to-end environments — from single rooms to enterprise-wide deployments.

System Design & Engineering
Installation & Integration
Programming & Ongoing Support

Trusted by enterprises, universities, and government organizations across the U.S.

Our Process

From Scope to Sign-Off

A structured delivery process designed to reduce risk and keep projects moving.

01

Plan

Discovery, site review, requirements gathering, and project alignment. We define scope, constraints, and success criteria before any design work begins.

  • Discovery calls & stakeholder interviews
  • On-site survey & infrastructure review
  • Requirements & use-case documentation
  • Project scope, timeline & milestone alignment
02

Engineer

System design, schematics, signal flow, BOM development, and documentation. Every project leaves this phase with a complete engineering package.

  • AV system design & signal flow diagrams
  • Equipment selection & BOM development
  • Rack layout & control system design
  • As-built documentation package
03

Deploy

Procurement, logistics, installation, programming, commissioning, and training. We own the delivery from first shipment to final handoff.

  • Authorized procurement & logistics coordination
  • Physical installation & cable management
  • Control system programming & configuration
  • Commissioning, testing & end-user training
04

Support

Monitoring, maintenance, lifecycle planning, and long-term service agreements. We stay engaged long after project close.

  • 24/7 remote system monitoring
  • Preventive & reactive maintenance
  • Technology lifecycle & refresh planning
  • Long-term service level agreements

A decade of delivery — trusted by 275+ clients across industries